BCHRX - ENTEC 321

  • MSDS: BCHRX
  • Manufacturer: BETZ ENTEC INC
  • Product Name: ENTEC 321
  • National Stock Number: 6850-00N001389
Product Identification

Product ID:ENTEC 321
MSDS Date:03/25/1988
FSC:6850
NIIN:00N001389
MSDS Number: BCHRX

Responsible Party
BETZ ENTEC INC
508 PRUDENTIAL RD
HORSHAM, PA 19044-2309
US

Emergency Phone: 215-674-9200

Info Phone: 215-674-9200 / FAX 215-674-5067

Preparer: HAROLD M. HERSH

Cage: 57394

Contractor
BETZDEARBORN INC.
TREVOSE,, PA 19053 US

Telephone: 215-942-3355

Cage: 57394

Ingredients

NON HAZARDOUS INGREDIENTS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: SKIN: SLIGHTLY IRRITATING. EYE:
SLIGHTLY IRRITATING. INHALATION: MISTS/AEROSOLS MAY CAUSE
IRRITATION TO THE UPPER RESPIRATORY TRACT. CHRONIC: NO EVIDENCE OF
POTENTIAL CHRONIC EFFECTS.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:MAY CAUSE REDNESS OR ITCHING OF SKIN.
IRRITATION AND/OR TEARING OF EYES (DIRECT CONTACT).
Medical Cond Aggravated by Exposure:NOT KNOWN.

First Aid

First Aid:SKIN: REMOVE CONTAM CLOTHING. WASH EXPOSED AREA W/A LG QTY OF
SOAP SOLUTION/H*2O FOR 15 MIN. EYE:IMMED FLUSH EYES W/H*2O FOR 15
MIN. IMMED CONTACT MD FOR ADDITIONAL TREATMENT. INHAL: REMOVE
VICTIM FRO M CONTAM AREA TO FRESH AIR. APPLY APPROP FIRST AID
TREATMENT AS NECESSARY. INGEST: DO NOT FEED ANYTHING BY MOUTH TO AN
UNCONCIOUS OR CONVULSIVE VICTIM. DILUTE CONTENTS OF STOMACH. INDUCE
(SUPP DATA)

Fire Fighting

Flash Point Method:SCC
Flash Point:>200F,>93C
Extinguishing Media:DRY CHEMICAL, CARBON DIOXIDE, FOAM OR WATER.
Fire Fighting Procedures:FIREFIGHTERS SHOULD WEAR POSITIVE PRESSURE
SELF CONTAINED BREATHNG APPARATUS (FULL FACE-PIECE TYPE).
FOAM/WATER CREATE A SLIPPERY CONDITION.SPREAD SAND OR GRIT.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:VENT AREA.USE SPECIFIED PROT EQUIP. CONTAIN &
ABSORB ON ABSORBENT MATL. PLACE IN WASTE DISP CNTNR. WASTE
CHARACTERISTICS OF ABSORBED MATL, OR ANY CONTAM SOIL,SHLD BE
DETERMINED IAW RCRA REGS. FLUSH AR EA W/H*2O.WET AREA MAY BE
SLIPPERY. USESAND/GRIT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:PROTECT FROM FREEZING. KEEP DRUMS &
PAILS CLOSED WHEN NOT IN USE.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN . IF VENTILATION IS INADEQUATE OR SIGNIFICANT
PRODUCT EXPOSURE IS LIKELY, USE A RESPIRATOR WITH DUST/MIST
FILTERS.
Ventilation:ADEQUATE VENTILATION.
Protective Gloves:RUBBER.
Eye Protection:SPLASH PROOF CHEMICAL GOGGLES.
Other Protective Equipment:EMERGENCY EYE WASH AND DELUGE SHOWER .
Work Hygienic Practices:IMMED REMOVE CONTAM CLOTHING. WASH BEFORE
REUSE. NORMAL CHEMICAL HANDLNG. WASH OFF GLOVES AFTER EACH
USE.REPLACE IF NEC.
Supplemental Safety and Health
SPECIFIC GRAVITY IS MEASURED AT 70F. FREEZING POINT: 26F. FIRST AID
PROC: VOMITING BY ONE OF THE STANDARD METHODS. IMMEDIATELY CONTACT
A PHYSICIAN.

Chemical Properties

HCC:N1
Vapor Pres:20
Vapor Density:<1
Spec Gravity:1.123
pH:5.3
Evaporation Rate & Reference:<1 (ETHER=1)
Solubility in Water:100
Appearance and Odor:LIGHT YELLOW LIQUID, MILD ODOR

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:THERMAL DECOMPOSITION (DESTRUCTIVE
FIRE) YIELDS ELEMENTAL OXIDES.

Disposal

Waste Disposal Methods:DISP IAW LOCAL,STATE & FED REGS . CONTAM H*2O
MAY BE SENT TO A SANITARY SEWER TREATMENT FACILITY IAW ANY LOCAL
AGREEMENT, A PERMITTED WASTE TREATMENT PLANT OR DISCHARGED UNDER A
NPDES PERMIT. PR ODUCT (AS IS) -INCINERATE/BURY IN APPRVD LANDFILL.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.